Karcher 600 CD manual Operation Of The System, Indication

Models: 600 CD

1 93
Download 93 pages 15.74 Kb
Page 40
Image 40
3.4.4.1Operating Messages for Normal Operation

OPERATION OF THE SYSTEM

WTC 600 LP / MP

Indication:

The equipment produces and starts with rejection. Operating conditions:

-„Production“ LED lights.

-“Reject“ LED lights.

RO 1000 V 01.34

Disposal

After the reject period has run off, normal production with rotating indication:

RO 1000 V 01.34

W-Temp:

hours meter

12.3°C

Production on

1111 h 11 min

perm: 12 µS/cm

 

 

 

 

 

When the RO equipment starts, the intake valve for untreated water is opened and the RO pump starts after the preset time and given pressure.

3.4.4.1Operating Messages for Normal Operation

1.System does not produce because tank is full:

-The “tank full” LED lights at the operating panel.

-Indication: “K. Displacement” and afterwards “Production off” on the display. Cause: The float switch in the drinking water tank has switched.

2.System does not produce during regeneration / flushing:

-The “regeneration” LED lights at the operating panel.

-Indication: “Forced stop” on the display.

Cause: One of the preliminary filters is being cleaned.

3.The system does not produce at malfunction indication: Metering station empty

-The “fault” LED lights.

-Indication: Hard water.

Cause: Empty sensor in the metering container delivers signal.

Corrective action: Refill metering container with chemical and acknowledge.

NOTE The malfunction indication can be acknowledged by pressing the ESC pushbutton; the rotating indications for normal operation appear again (see above).

40

Service Handbook 08.2004

Page 40
Image 40
Karcher 600 CD manual Operation Of The System, Indication, 3.4.4.1Operating Messages for Normal Operation