MAINTENANCE | WTC 600 LP / MP |
4.6Maintenance Plan
4.6.1Maintenance During Operation
Module | Cycle / Time | Activity | Chap./Fig. |
RO module: Flow meter | Daily | Check drinking water capacity | 3.3.1.2, |
|
|
| (11/6) |
|
|
|
|
RO module: Differential | Daily | Check pump and concentrate | (1/13) |
pressure |
| pressure | (1/14) |
|
|
|
|
RO control: Display | Daily | Check drinking water | (1/11) |
|
| conductance value |
|
|
|
|
|
Metering container | Weekly | Check filling and refill | 3.2 |
|
|
|
|
Media filter/activated carbon | Weekly | Automatic backwashing (check | 3.4.2.4 |
filter |
| operation meter) |
|
|
|
|
|
Control sheet | Weekly | Fill out | Appendix |
|
|
|
|
Metering stations | Every 4 weeks | Clean and flush metering | 4.2 |
|
| container |
|
Float switch, drinking | Every 4 weeks | Visual check of switch |
|
water tank |
|
|
|
|
|
|
|
Metering stations | Yearly or every | Clean intake and pressure | 4.2 |
| 4000 hours | valves |
|
|
|
|
|
Metering stations | Yearly or every | Replace membrane | 4.2 |
| 4000 hours |
|
|
|
|
|
|
Fine filter | Every 3 | Replace filter | 4.1 |
| months |
|
|
|
|
|
|
|
|
|
|
RO module (when conserved) | Every 6 | Renew conservation | 4.4.4 |
| months |
|
|
|
|
|
|
Tabelle 32 |
|
|
|
60 | Service Handbook 08.2004 |