WTC 600 LP / MP | MAINTENANCE |
4.5.4Malfunctions – Media and Activated Carbon Filter, Fine Filter and Flocculation
Indication | Malfunction | Cause | Corrective Action | Chap./Fig. |
|
|
|
|
|
More than one | Backwashing is | Load of debris | Install suitable preliminary | 3.4.2.4 |
backwashing | initiated too often | too high | treatment; consultation | Tab. 24 |
per day |
|
| through sales |
|
(diagnosis |
|
|
|
|
controller) |
|
|
|
|
|
|
|
|
|
| Backwashing no | Pump defective | Replace pump or |
|
| sufficient |
| repair |
|
|
| Intake side of | Clean |
|
|
| pump clogged |
|
|
|
|
|
|
|
|
| Intake side of | Shorter line |
|
|
| pump too long | notify sales |
|
|
|
|
|
|
| Sand | Heavily soiled | Notify sales |
|
| conglutinated | water |
|
|
|
|
|
|
|
Differential | Filtrate of the sand | Small particles | Install preliminary | 4.1 |
pressure of | filter turbid | come through | treatment |
|
fine filter quickly |
|
|
|
|
exceeds 1 bar |
|
|
|
|
|
|
|
|
|
| Filtrate of the | Small particles | Check sand filter; | 4.1 |
| activated carbon | come through | install preliminary |
|
| filter turbid |
| treatment as required |
|
| Filter material | No backwashing | Carry out backwashing; | 3.4.2.1 |
| conglutinated | carried out for too | if without success, |
|
|
| long | replace sand |
|
|
|
|
|
|
|
| Too much | Reduce metering amount |
|
|
| flocculation agent | of flocculation agent; |
|
|
| added | carry out backwashing |
|
|
|
|
|
|
Indication of the |
| Power supply | Notify electrician |
|
controller |
| disconnected |
|
|
remains dark |
|
|
|
|
|
|
|
|
|
Control wheel |
| Control switch or | Replace controller |
|
does not stand |
| switching |
|
|
still |
| mechanism |
|
|
|
| defective |
|
|
|
|
|
|
|
No changes of | Backwashing is | Controller | Change | 3.4.2.4 |
the “back- | not initiated | incorrectly | programming |
|
washing” |
| programmed |
|
|
counter |
|
|
|
|
|
|
|
|
|
Tabelle 31 |
|
|
|
|
Service Handbook 08.2004 | 59 |