Karcher 600 CD WTC 600 LP / MP, 3.4.3.4Selecting Several Arguments at the Same, Initial situation

Models: 600 CD

1 93
Download 93 pages 15.74 Kb
Page 35
Image 35
3.4.3.4Selecting Several Arguments at the Same

WTC 600 LP / MP

OPERATION OF THE SYSTEM

3.4.3.4Selecting Several Arguments at the Same

For this a series of “0” (argument inactive) and “1” (argument active) appears on the bottom line of the display. With help of the pushbutton and the pushbutton, a cursor can be moved between the individual characters. The activation / inactivation of an argument is carried out with the pushbutton and the pushbutton respectively. Storing is carried out through pressing the RETURN pushbutton (Example: See Chapter 3.4.3.7).

3.4.3.5Adjusting Operating Parameters and Balancing Values

For adjustment of operating parameters (e. g. via a menu), the name of the operating parameter appears in the upper line and the current value is shown in the bottom line. A flashing cursor marks the respective changeable figure, which can be adjusted to the desired value by pressing the pushbutton and the pushbutton. With help of the pushbutton and the pushbutton, the marking can be slid to the respective other figure. Storing is carried out through pressing the RETURN pushbutton; the input can be cancelled by pressing the ESC pushbutton.

3.4.3.6Acknowledging Data Inputs

To avoid input errors, acknowledgments are required at various menu locations. They request the user again to acknowledge changes of operational settings / parameters and adjustments as correct.

For acknowledgment the pushbutton and afterwards the RETURN pushbutton must be pressed.

3.4.3.7De-conserving

The RO system leaves the factory conserved. Therefore, the conservation liquid must be flushed out before the initial startup.

Initial situation:

The pre-filters have been put into service. The filter insert has been inserted at the fine filter 5µ. After all the water pipes and float switch have been connected, the drinking water pipe to the tank must be undone and temporarily fed to the wastewater sewer.

Work steps:

-Master switch on: system is in switched off operating mode

-Temporarily lay the drinking water pipe in the sewer

-Flush / purge system:

-Pressure regulating valve (4.17) fully open (lever horizontal)

-Concentrate regulating valve (4.15) half open (45°).

The following message must be indicated on the display:

RO 1000 V 01.34

Stop

Otherwise press the ESC pushbutton 5 times.

Then enter user password (cf. Chap. 3.4.3.1).

Service Handbook 08.2004