Karcher 600 CD WTC 600 LP / MP, Maintenance, Indication, Malfunction, Cause, Corrective Action

Models: 600 CD

1 93
Download 93 pages 15.74 Kb
Page 57
Image 57
Manual background

WTC 600 LP / MP

MAINTENANCE

4.5.2Malfunction Indication at the Operating Panel

The control system detects operational malfunctions only while in operation operating mode; these are indicated on the display. The occurrence of an error usually leads to the complete system being switched off (production is interrupted).

Indication

Malfunction

Cause

Corrective Action

Chap./

 

 

 

 

Fig.

 

 

 

 

 

Motor/

Metering containe

 

Fill up

3.2

hard water

empty

 

 

 

 

 

 

 

 

Lack of pressure

PI station gene-

No water

Establish the flow of

 

 

rates no pressure

available

untreated water again

 

 

 

 

 

 

 

 

Air in the pump

Bleed the pump; connect

 

 

 

 

pump directly in canal,

 

 

 

 

run for 30 sec.

 

 

 

 

 

 

 

 

Suction height too

Ensure supply pressure

 

 

 

high, pump is not

to the pump (mains

 

 

 

self-priming

supply, submerged

 

 

 

 

pump, ... )

 

 

 

 

 

 

 

Supply pressure of

Flow rate through

see 4.5.4

 

 

the reverse

preliminary filter

 

 

 

osmosis too low

too low

 

 

 

 

 

 

 

 

Differential

Filter soiled

Replace filter cartridge

4.1

 

pressure of the

 

 

 

 

preliminary filter

 

 

 

 

>>1 bar

 

 

 

 

 

 

 

 

 

Pressure switch

 

Replace pressure

2.2,

 

defective

 

switch (pay attention to

Pos. 4.9

 

 

 

setting)

 

 

 

 

 

 

 

Flow rate in sand

Filter clogged

Initiate backwashing

3.4.2

 

filter too low

 

 

 

 

 

 

 

 

Conductance

Permeate

Yield too high

Increase flow of

3.4.3.7

value

conductance value

 

concentrate

 

exceeded

too high

 

 

 

 

 

 

 

 

 

 

Very high salt

Check cause;

1)

 

 

 

 

 

content in

notify sales dept.

 

 

 

untreated water

 

 

 

 

 

 

 

 

 

Defective seal or

Replace parts; switch off

ETL

 

 

membrane

system, if required

 

 

 

 

 

 

 

Conductance

 

Calibrate again;

ETL, SLP

 

value probe

 

replace if required

 

 

defective

 

 

 

 

 

 

 

 

Table 29

 

 

 

 

1)See untreated water analysis, operational start-up record

Service Handbook 08.2004