APPENDIX | WTC 600 LP / MP | |
3 | Operational Scope |
|
3.1Operating settings
The control system allows to preselect the following operating settings (realization see item 4). The resulting control behaviours are described in the chapter Operating Conditions. The standard values (setting after parameter reset) are marked by * in the appropriate field.
ps LIM high | function: | Preselect if unit is to be switched off if |
|
| LIM is exceeded or if a failure |
|
| message is sufficient |
| right of access: | user/technician |
| possible setting: | * switch off do |
|
| not switch off |
ps acknowledgment | function: | Prelesect if acknowledgment of |
|
| failures is possible in the normal level |
|
| (=without password) |
|
| or only in the user/technician level |
|
| (=with password). |
| right of access: | technician |
| possible setting: | * without password |
|
| with password |
ps concentrate mode | function: | Preselect if PRODUCTION has to be |
|
| followed by CONCENTRATE FLUSH |
|
| (with pump) or CONCENTRATE |
|
| DISPLACEMENT (without pump). |
| right of access: | technician |
| possible setting: | * flush |
|
| displacement |
ps tank type | function: | Prelesect if tank is equipped with an |
|
| overflow or not. Should the tank have |
|
| an overflow, the produced water |
|
| continues to flow into the tank during |
|
| CONCENTRATE DISPLACEMENT/ |
|
| FLUSH and DISCONTINUOUS |
|
| RINSE. |
| right of access: | technician |
| possible setting: | * with |
|
| without overflow |
74 | Service Handbook 08.2004 |