Command Name | Short | Default | Parameter | Description | |
|
|
|
|
| |
PERSIST | PE | 128 | 0 ~ 255 | Specifies a parameter to calculate probability for the | |
PERSIST/SLOTTIME method. | |||||
|
|
|
| ||
|
|
|
|
| |
PPERSIST | PP | ON | ON/ OFF | Causes the TNC to use the PERSIST/SLOTTIME method | |
when ON, or the DWAIT method when OFF. | |||||
|
|
|
| ||
|
|
|
|
| |
RESET | RESET | — | — | Restores the default status for all the commands. | |
|
|
|
|
| |
RESPTIME | RES | 5 | 0 ~ 250 | Specifies the acknowledgment packet transmission delay. | |
The unit of the parameter is 100 milliseconds. | |||||
|
|
|
| ||
|
|
|
|
| |
RESTART | RESTART | — | — | Causes the TNC to function as if it is switched OFF then ON. | |
|
|
|
|
| |
|
|
|
| Specifies the number of transmission retries. If packets are | |
RETRY | RE | 10 | 0 ~ 15 | not correctly accepted while in connection, a connect request | |
|
|
|
| is sent again after the specified number of retries. | |
|
|
|
|
| |
SENDPAC | SE | $0D | 0 ~ $7F | Specifies a character which forces a packet to be sent. | |
|
|
|
|
| |
|
|
|
| Specifies the period of random number generation intervals | |
SLOTTIME | SL | 3 | 0 ~ 250 | for the PERSIST/SLOTTIME method. The unit of the | |
|
|
|
| parameter is 10 milliseconds. | |
|
|
|
|
| |
TRACE | TRAC | OFF | ON/ OFF | When ON, causes the TNC to display all received packets in | |
their entirety. | |||||
|
|
|
| ||
|
|
|
|
| |
TRIES | TRI | 0 | 0 ~ 15 | Specifies the number of transmission retries programmed in | |
the retry counter. | |||||
|
|
|
| ||
|
|
|
|
| |
TXDELAY | TX | 50 | 0 ~ 120 | Specifies the time delay between PTT ON and start of | |
transmission. The unit of the parameter is 10 milliseconds. | |||||
|
|
|
| ||
|
|
|
|
| |
|
|
| Call1 (VIA | Specifies call signs to send a packet in Unprotocol mode. | |
UNPROTO | U | CQ | call2, call3, ... | Call1 is the call sign of the destination. Call2 to call9 are call | |
|
|
| call9) | signs of stations to be digipeated through. | |
|
|
|
|
| |
XFLOW | X | ON | ON/ OFF | Causes the TNC to perform software flow control when ON, or | |
hardware flow control when OFF. | |||||
|
|
|
| ||
|
|
|
|
|