Device - OCP tab | The OCP tab is used to setup options on the scanner’s Operator |
| Control Panel (i.e., touchscreen). |
Function Keys — available functions for each key are:
•(none)
•Stop Scanning: scanning will stop and control will return to the scanning application (i.e., ends the job). Restart the scan session from the scanning application.
•End Batch: start a new batch by resetting the batch count (i.e. How Many to Count) and continue to scan.
•Omit Multifeed: turn off multifeed detection only on the next document that is fed.
•Omit Print: turn off printing only on the next document that is fed.
•Omit Patch: turn off patch recognition only on the next document that is fed.
•Lower Elevator: moves the elevator to the lowest position.
NOTE: The End Batch and Omit Patch options are only available when the scanner is in Image Address mode.
|