Chapter 6: Configuration Using Web Manager

Figure 6-5. Channel Serial Settings

2. In the available fields, enter the following information:

Channel 1

Disable Serial Port

When selected, disables communication through the serial port. The serial port is enabled by default.

Port Settings

Protocol

From the drop-down menu, select the protocol type for the

 

selected channel. The default setting is RS232.

 

Note: Configuring RS-485 is not permitted.

Flow Control

Flow control manages data flow between devices in a network

 

to ensure the data is processed efficiently. Too much data

 

arriving before a device is prepared to manage it causes lost

 

or retransmitted data. None is the default setting.

Baud Rate

The unit and attached serial device, such as a modem, must

 

agree on a speed or baud rate to use for the serial connection.

 

Valid baud rates are 300, 600, 1200, 2400, 4800, 9600

 

(default), 19200, 38400, 57600, 115200, or 230400.

Data Bits

Indicates the number of bits in a transmitted data package.

 

The default setting is 8.

Parity

Checks for the parity bit. The default setting is None.

 

 

Stop Bits

The stop bit follows the data and parity bits in serial

 

communication. It indicates the end of transmission. The

 

default setting is 1.