IBM 390, 387, 393, 391, 389, 388, 441, 392 Removing the EMI-protective panel, ThinkServer User Guide

Models: 392 390 441 388 389 391 393 387

1 210
Download 210 pages 3.89 Kb
Page 142
Image 142

3.The non-hot-swap hard disk drive(s) are installed in the lower hard disk drive cage and are protected by an EMI-protective panel. Press the small tab 1 on the EMI-protective panel from the bottom and then pivot the EMI-protective panel upward to remove it from the chassis and gain access to the non-hot-swap hard disk drive bays.

2 1

CPU

MEM

PSU

Figure 67. Removing the EMI-protective panel

4.Remove the server cover. See “Removing the server cover” on page 85.

5.Remove the front system fan 1. See “Replacing the front system fan” on page 149.

6.Locate the appropriate non-hot-swap hard disk drive bay. See “Server components” on page 25.

7.Touch the static-protective package that contains the new non-hot-swap hard disk drive to any unpainted surface on the outside of the server. Then, take the new non-hot-swap hard disk drive and the signal cable out of the package.

Note: Do not touch the circuit board on the hard disk drive.

130ThinkServer User Guide

Page 142
Image 142
Lenovo 390, 387, 393, 391, 389, 388, 441, 392 manual Removing the EMI-protective panel, ThinkServer User Guide