IBM 441 BMC setting jumper, BIOS recovery jumper, Clear password jumper, Manufacturing jumper

Models: 392 390 441 388 389 391 393 387

1 210
Download 210 pages 3.89 Kb
Page 61
Image 61

3.Lay the server on its side for easier operation.

4.Locate the Clear CMOS /Recovery jumper on the system board and then move the jumper from the default normal position (pin 1 and pin 2) to the short-circuited position (pin 2 and pin 3).

5.Wait more than 10 seconds and then move the Clear CMOS /Recovery jumper back to the normal position (pin 1 and pin 2).

6.Reinstall the server cover and connect the power cord(s). See “Completing the parts replacement” on page 162.

7.Wait about 30 seconds. Then, turn on the server. The BIOS passwords are erased and the BIOS recovers to the factory default settings.

2

BMC setting jumper

When the BMC setting jumper is in the default normal position (pin 1 and pin 2), the server needs about 30 seconds for the BMC to initialize whenever you connect the server to an ac power source. If you press the power switch on the front panel during this period, the server will not start immediately; it will start after the BMC initialization finishes.

If you move the BMC setting jumper to pin 2 and pin 3, the server will be directly turned on when you press the power switch without waiting for the BMC ready. The BMC function might not be available in this situation.

3

BIOS recovery jumper

Set the jumper and boot the server from a BIOS recovery image in order to recover your BIOS settings.

To recover the BIOS, see “Recovering from a BIOS update failure” on page 68.

4

Clear password jumper

Used to erase forgotten passwords, such as an administrator password and a user password.

To clear passwords, do the following:

1.Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all power cords from electrical outlets and disconnect all cables that are connected to the server.

2.Remove the server cover. See “Removing the server cover” on page 85.

3.Lay the server on its side for easier operation.

4.Locate the Clear password jumper on the system board and then move the jumper from the default normal position (pin 1 and pin 2) to the short-circuited position (pin 2 and pin 3).

5.Wait more than 10 seconds and then move the Clear password jumper back to the normal position (pin 1 and pin 2).

6.Reinstall the server cover and connect the power cord(s). See “Completing the parts replacement” on page 162.

7.Wait about 30 seconds. Then, turn on the server. The BIOS passwords are erased, including the administrator password and user password.

8.To set new passwords, see “Using passwords” on page 65.

5

Manufacturing jumper

Reserved for the manufacturer.

Chapter 3. Product overview 49

Page 61
Image 61
Lenovo 441, 387, 393, 391, 389, 388, 390 BMC setting jumper, BIOS recovery jumper, Clear password jumper, Manufacturing jumper