TROUBLESHOOTING & REPAIR

F-12

 

 

 

MAIN INVERTER BOARD RESISTANCE TEST (continued)

FIGURE F.2

P1

LEAD 2 (NZL)

WRK

LEAD 3 (EL)

Plug J1

Harness

Plug

RIGHT SIDE OF MACHINE

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove main input power to the PRO-CUT 25.

2.Remove carrying handle using a 4mm allen wrench.

3.Using a crescent wrench, carefully remove the plastic nut from around the pressure regulator located on the top of the machine.

4.Using a 7mm nut driver, remove the case wraparound.

5.Perform the Input Filter Capacitor Discharge Procedure detailed earlier in this section.

6.Visually check for burned or damaged compo- nents. If any components are physically dam- aged or determined to be faulty, the Main Inverter Board should be replaced.

7.Check the input rectifier bridge (P1) for shorts or opens. See Figure F.2