TROUBLESHOOTING & REPAIR | |||||||
|
|
|
|
|
| ||
| Observe Safety Guidelines |
|
| TROUBLESHOOTING GUIDE | |||
| detailed in the beginning of this manual. |
|
|
|
|
| |
|
|
|
|
|
| ||
| PROBLEMS | POSSIBLE AREAS OF | RECOMMENDED |
|
| ||
| (SYMPTOMS) | MISADJUSTMENT(S) |
| COURSE OF ACTION |
|
| |
|
|
|
|
|
|
| |
|
| LED FUNCTION PROBLEMS |
|
|
|
| |
| The Thermal LED is lit after normal 1. One of the machine’s | thermal | 1. | Check all connectors and wires | |||
| use. | protection circuits has | tripped. |
| for loose or faulty connections. | ||
|
| Do not turn the |
| See Wiring Diagram. |
|
| |
|
| Allow the machine to cool. The | 2. | The inverter board may | be | ||
|
| thermal protection circuits will | |||||
|
|
| faulty. Replace. |
|
| ||
|
| reset themselves. |
|
|
|
| |
|
|
|
|
|
|
| |
|
| 2. Either the duty cycle has been | 3. The control board may be faulty. | ||||
|
|
| Replace. |
|
| ||
|
| exceeded, the fan is not func- |
|
|
| ||
|
|
|
|
|
| ||
|
| tioning, or the louvers are | 4. | Use the correct extension cord. | |||
|
| blocked. |
|
| See the instruction manual. |
|
|
3.Thermo light comes on when over voltage occurs
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call