Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-7

TROUBLESHOOTING & REPAIR

F-7

Observe Safety Guidelines

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

FUNCTION PROBLEMS

 

 

 

Will only cut thin gauge material or

The ground lead or clamp is dis-

1.

Replace or repair, clamp or

cutting cutting is 1/2 of what it

connected. Unit is not transferring

 

cable.

 

should be. Cuts for 3

seconds

to cut mode.

2.

Clamp directly to the piece to

then quits.

 

 

 

 

 

be cut.

 

 

 

 

 

 

 

 

 

3.

Look for the transfer signal from

 

 

 

 

the inverter board to the control

 

 

 

 

Board per the enhanced dia-

 

 

 

 

gram.

 

 

 

 

4.

Possible replacement

of the

 

 

 

 

inverter board per the signal of

 

 

 

 

the enhanced diagram.

 

 

 

 

5.

Possible replacement

of the

 

 

 

 

Control Board per the signal of

 

 

 

 

the enhanced diagram.

 

 

 

 

6.

Use the correct extension cord.

 

 

 

 

See the instruction manual.

 

 

 

 

When nothing is described for your

 

1.

Unplug and re-plug in all the

problem, or you have performed

 

 

printed circuit board

harness

your test with no solution.

 

 

 

connectors.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

PRO-CUT 25

Page 41
Image 41
Lincoln Electric SVM149-A service manual Troubleshooting & Repair