F-9

TROUBLESHOOTING & REPAIR

F-9

INPUT FILTER CAPACITOR DISCHARGE PROCEDURE

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

DESCRIPTION

This procedure will drain off any charge stored in the four capacitors that are part of the Inverter Board assembly. This procedure MUST be performed, as a safety precaution, before conducting any test or repair procedure that requires you to touch internal components of the machine.

MATERIALS NEEDED

4mm Allen Wrench

Volt/Ohmmeter

7mm Nut Driver

Crescent Wrench

Insulated Gloves

Insulated Pliers

High Wattage Resistor - 25 to 1000 ohms, 25 watts minimum

PRO-CUT 25

Page 43
Image 43
Lincoln Electric SVM149-A service manual Input Filter Capacitor Discharge Procedure, Description