Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-4

TROUBLESHOOTING & REPAIR

F-4

Observe Safety Guidelines

 

 

 

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

Major physical or electrical dam-

1. Contact your local authorized

1.

Contact the Lincoln

Electric

age is evident when the sheet

 

Lincoln Electric Field Service

 

Service Department,

 

metal cover(s) are removed.

 

 

Facility for technical assistance.

 

1-888-935-3877

 

 

 

 

 

 

 

 

 

 

 

 

 

Machine is dead – no output – no

1.

Make sure that the input power

1.

Check the input power switch

fan – no status indicator lights.

 

switch is in the “ON” position.

 

for proper operation.

 

 

 

2.

Check the input voltage at the

2.

Check the leads associated

 

 

 

machine.

Input voltage must

 

with the power switch for loose

 

 

 

match the rating plate.

 

or faulty connections.

See the

 

 

3. Check for

blown or missing

 

Wiring Diagram.

 

 

 

 

 

 

 

 

 

fuses in the input lines and the

3.

Check all connectors and wires

 

 

 

1A slow blow fuse on the input

 

for loose or faulty connections.

 

 

 

board.

 

4.

Perform the Input

Voltage

 

 

 

 

 

 

 

 

 

 

 

Board Test.

 

 

 

 

 

 

Machine is malfunctioning - no

1.

Check the input voltage at the

1.

Check all connectors and wires

output - no status indicator lights -

 

machine.

Input voltage must

 

for loose or faulty connections.

fans run.

 

 

match the rating plate.

 

See Wiring Diagram.

 

 

 

 

 

 

2.

Perform the Input

Voltage

 

 

 

 

 

 

Board Test.

 

 

 

 

 

 

3.

The control board may be

 

 

 

 

 

 

faulty. Replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.

PRO-CUT 25

Page 38
Image 38
Lincoln Electric SVM149-A service manual Output Problems