TROUBLESHOOTING & REPAIR | |||||||
Observe Safety Guidelines |
|
|
|
| TROUBLESHOOTING GUIDE | ||
detailed in the beginning of this manual. |
|
|
|
|
| ||
|
|
|
|
| |||
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
| |||
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION | ||||
|
|
|
|
|
|
| |
|
|
| OUTPUT PROBLEMS |
|
|
| |
Major physical or electrical dam- | 1. Contact your local authorized | 1. | Contact the Lincoln | Electric | |||
age is evident when the sheet |
| Lincoln Electric Field Service |
| Service Department, |
| ||
metal cover(s) are removed. |
|
| Facility for technical assistance. |
|
| ||
|
|
|
|
|
|
| |
|
|
|
|
| |||
Machine is dead – no output – no | 1. | Make sure that the input power | 1. | Check the input power switch | |||
fan – no status indicator lights. |
| switch is in the “ON” position. |
| for proper operation. |
| ||
|
| 2. | Check the input voltage at the | 2. | Check the leads associated | ||
|
|
| machine. | Input voltage must |
| with the power switch for loose | |
|
|
| match the rating plate. |
| or faulty connections. | See the | |
|
| 3. Check for | blown or missing |
| Wiring Diagram. |
| |
|
|
|
|
| |||
|
|
| fuses in the input lines and the | 3. | Check all connectors and wires | ||
|
|
| 1A slow blow fuse on the input |
| for loose or faulty connections. | ||
|
|
| board. |
| 4. | Perform the Input | Voltage |
|
|
|
|
| |||
|
|
|
|
|
| Board Test. |
|
|
|
|
|
| |||
Machine is malfunctioning - no | 1. | Check the input voltage at the | 1. | Check all connectors and wires | |||
output - no status indicator lights - |
| machine. | Input voltage must |
| for loose or faulty connections. | ||
fans run. |
|
| match the rating plate. |
| See Wiring Diagram. |
| |
|
|
|
|
| 2. | Perform the Input | Voltage |
|
|
|
|
|
| Board Test. |
|
|
|
|
|
| 3. | The control board may be | |
|
|
|
|
|
| faulty. Replace. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call