F-4

TROUBLESHOOTING & REPAIR

F-4

 

 

 

 

 

 

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

 

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

 

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

Major physical or electrical

1. Contact your local Lincoln

1. Contact the Lincoln Electric

 

damage is evident.

 

Authorized Field Service

Service Dept.

 

 

 

Facility.

1-888-935-3877.

 

 

 

 

 

Machine is dead - no open

1. Make sure correct voltage is

1. Check input power switch

 

circuit voltage, wire feed, gas

applied to the machine.

(S1) it may be faulty. See

 

flow when trigger is pulled and

2. Make certain that the power

Wiring Diagram.

 

fan does not operate.

 

 

 

 

switch is in the “on” position.

2. Check lead connection and

 

 

 

 

 

 

3. Blown fuses in the input line.

correct function of circuit

 

 

 

breaker. See Wiring

 

 

 

Check circuit breaker on the

 

 

 

Diagram.

 

 

 

machine.

 

 

 

 

 

 

 

 

3. The Control P.C. Board may

 

 

 

 

be faulty

 

 

 

 

 

No weld output, wire feed, gas

1. The thermostat may be open

1. Check thermostat and

 

flow when the trigger is pulled.

due to machine overheating. If

associated leads for loose or

Fan does run.

 

machine operates normal after

broken connections. See

 

 

 

a cooling off period then check

wiring diagram.

 

 

 

for proper fan ventilation,

2. Remove main power supply to

 

 

remove any obstructions. Make

 

 

certain that the machine’s duty

the machine. With the gun

 

 

 

trigger pulled check for

 

 

 

cycle is not being exceeded.

 

 

 

continuity at pins 6 and 3 on

 

 

 

 

 

2. Gun trigger may be faulty.

plug J5 on the control board.

 

 

 

3. Perform the Transformer Test.

 

 

 

4. Check all heavy current

 

 

 

 

carrying leads. Check for loose

 

 

 

or broken connections at the

 

 

 

transformer, choke and

 

 

 

 

rectifier.

 

 

 

 

5. Make sure identity plug is not

 

 

 

missing on control board. See

 

 

 

Wiring Diagram.

 

 

 

 

6. Possible bad control board.

 

 

 

 

Replace.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 1-888-935-3877.