TROUBLESHOOTING & REPAIR | ||||
|
|
| ||
|
|
| ||
Observe Safety Guidelines detailed in the beginning of this manual. |
|
| ||
|
|
|
|
|
PROBLEMS |
| POSSIBLE AREAS OF | RECOMMENDED |
|
(SYMPTOMS) |
| MISADJUSTMENT(S) | COURSE OF ACTION |
|
|
|
|
|
|
|
| OUTPUT PROBLEMS |
|
|
Major physical or electrical | 1. Contact your local Lincoln | 1. Contact the Lincoln Electric |
| |
damage is evident. |
| Authorized Field Service | Service Dept. |
|
|
| Facility. |
| |
|
|
|
| |
Machine is dead - no open | 1. Make sure correct voltage is | 1. Check input power switch |
| |
circuit voltage, wire feed, gas | applied to the machine. | (S1) it may be faulty. See |
| |
flow when trigger is pulled and | 2. Make certain that the power | Wiring Diagram. |
| |
fan does not operate. |
|
|
| |
| switch is in the “on” position. | 2. Check lead connection and |
| |
|
|
| ||
|
| 3. Blown fuses in the input line. | correct function of circuit |
|
|
| breaker. See Wiring |
| |
|
| Check circuit breaker on the |
| |
|
| Diagram. |
| |
|
| machine. |
| |
|
|
|
| |
|
|
| 3. The Control P.C. Board may |
|
|
|
| be faulty |
|
|
|
|
| |
No weld output, wire feed, gas | 1. The thermostat may be open | 1. Check thermostat and |
| |
flow when the trigger is pulled. | due to machine overheating. If | associated leads for loose or | ||
Fan does run. |
| machine operates normal after | broken connections. See |
|
|
| a cooling off period then check | wiring diagram. |
|
|
| for proper fan ventilation, | 2. Remove main power supply to | |
|
| remove any obstructions. Make | ||
|
| certain that the machine’s duty | the machine. With the gun |
|
|
| trigger pulled check for |
| |
|
| cycle is not being exceeded. |
| |
|
| continuity at pins 6 and 3 on | ||
|
|
| ||
|
| 2. Gun trigger may be faulty. | plug J5 on the control board. | |
|
|
| 3. Perform the Transformer Test. | |
|
|
| 4. Check all heavy current |
|
|
|
| carrying leads. Check for loose | |
|
|
| or broken connections at the | |
|
|
| transformer, choke and |
|
|
|
| rectifier. |
|
|
|
| 5. Make sure identity plug is not | |
|
|
| missing on control board. See | |
|
|
| Wiring Diagram. |
|
|
|
| 6. Possible bad control board. |
|
|
|
| Replace. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call