Lincoln Electric SVM189-B service manual Abnormal Open Circuit Voltage Waveform

Models: SVM189-B

1 111
Download 111 pages 41.07 Kb
Page 78
Image 78

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

F-24

TROUBLESHOOTING & REPAIR

F-24

 

ABNORMAL OPEN CIRCUIT VOLTAGE WAVEFORM

C1

0 volts

10Volts

20ms

This is NOT the typical voltage wave- form. The output capacitor was dis- connected from the circuit. Note the increased ripple in the waveform. This condition simulates the faulty output filter capacitor. Each vertical division represents 10 volts and that each hor- izontal division represents 20 millisec- onds in time.

Note: Scope probes connect at the machine output terminals. Positive probe to (+) terminal, negative probe to (-) terminal.

SCOPE SETTINGS

Volts/Div

10V/Div.

Horizontal Sweep ...

20 ms/Div.

Coupling

DC

Trigger

Internal

 

 

COMPACT WIRE WELDERS

Page 78
Image 78
Lincoln Electric SVM189-B service manual Abnormal Open Circuit Voltage Waveform