Windows CE

Ethernet

2ETHERNET

The Ethernet interface is implemented in compliance with the IEEE 802.3 (10/100BASE-T) standard. The network is implemented with shielded twisted-pair cables and shielded RJ45 plugs. The devices networked with the MICRO PANEL must also be provided with shielded connections. The twisted-pair cable selected for use in Ethernet networks must comply with the cable specifications with regard to cable length and transmission speed. See also specification to EIA/TIA 568 TSB-36.

The cables of the Ethernet interface must be laid separately from the low-voltage cables.

2.1ACCESS TO PC

Network name

Each panel is given a unique network name in order to avoid conflicts within a network. When the panel is started, the name is displayed together with its relevant IP address. A device name must only occur once in the same network.

Caution:

With Windows CE it is only possible to access external resources (drives/directories/printers) via names and not via IP addresses. Further information is provided in chapters Name resolution in Windows networks, Network access procedure and Network test.

User name / Password / Domain:

The MICRO PANEL has the following default settings:

User name:

MI_PANEL

Password:

No password defined

Domain:

No domain defined

The settings can be modified with the Owner program.

Note:

The user name and password must always be given to access a PC!

Examples of external access:

Direct access to the computer resources is possible or via the local directory \Network\«EnableName». All computer resources associated with the net use command are listed in the directory \NETWORK of the MICRO PANEL. The use of the net use command is described in chapter Network access procedure.

Direct access to computer resource:

Examples:

\\«Network name of the computer»\«Printer name»

\\PC-001\ColorPrinter

\\«Network name of the computer»\«Directory»

\\PC-001\transfer

Access via «connected» resources

 

\Network\«mapped printer name»

\Network\HP6940

\Network\«mapped directory name»

\Network\pc001

The name of the computer must be specified under «Network name of the computer». IP addresses are not supported here. Enter the name of the enabled printer under «Printer name».