14-12. Resetting Memory

Press Mode

Access Select Setup

Display

5

Wiretype

Display

>Memory Shutdown

1

>No Reset

Increase/

Decrease

> Program 1

Reset

Press

2

Parameter

1 No Reset

Press Parameter Select button to exit memory reset parameter with- out resetting any data.

2 Program Reset

Press Parameter Select button to reset last active program to original factory program settings. All other program and setup information remains the same. If setup card is in card slot, program will be loaded from card.

3 System Reset

Press Parameter Select button to reset programs and setup to original factory settings. System, Arc Time, and Robot Control settings are not affected by the system reset. If setup card is in card slot, program will be loaded

> Process

> Prg 1

Sequence

Pulse

SharpArc

035” Steel

Card

Argon – Oxy

Select

Increase/

Decrease

> System

3

Reset

Press

Parameter

from card.

4 Total Reset

Press Parameter Select button to reset programs and setup to origi- nal factory settings for all programs and setup including System and Arc Time. If setup card is in card slot, program will be loaded from card.

5 Reset (Default) Displays

Select

Increase/

Decrease

> Total

4

Reset

Press

Parameter

Select

14-13. Selecting Arc Start/Volt Sense Error Shutdown

Access

Setup

Display

Press Mode

Select

Display

Memory

>Shutdown Name

1

Arc Start/

Volt Sense

>On

Increase

Arc Start/

 

 

Volt Sense

 

> Off

1 Voltage Shutdown Display

With Arc Start/Volt Sense on, the unit shuts down when no arc voltage is sensed. If the unit shuts down, an error message appears (see Section 5-5).

With Arc Start/Volt Sense off, the unit continues to feed wire even when there is no arc voltage sensed.