3-5. Weld Output Terminals And Selecting Cable Sizes

 

 

 

Total Cable (Copper) Length In Weld Circuit Not Exceeding

 

 

 

30 m (100 ft) Or Less

45 m

60 m

70 m

90 m

105 m

120 m

 

 

(150 ft)

(200 ft)

(250 ft)

(300 ft)

(350 ft)

(400 ft)

 

 

 

 

 

Welding

10 – 60%

60 – 100%

 

 

10 – 100% Duty Cycle

 

 

 

Amperes

Duty Cycle

Duty Cycle

 

 

 

 

 

 

 

 

 

 

 

 

100

25

25

25

35

35

50

55

55

 

150

35

35

35

50

55

70

95

95

 

200

35

35

50

55

70

95

120

120

 

250

35

50

55

70

95

120

2-70

2-70

 

300

50

55

70

95

120

2-70

2-95

2-95

Positive

350

55

70

95

120

2-70

2-95

2-95

2-120

 

 

 

 

 

 

 

 

 

(+)

400

55

70

95

120

2-70

2-95

2-120

2-120

Negative

(–)

500

70

95

120

2-70

2-95

2-120

3-95

3-95

 

Ref. 801 914-A

600

95

120

2-70

2-95

2-120

3-95

3-120

3-120

 

*Weld cable size (mm2) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007E

3-6. 115 Volts AC Duplex Receptacle And Circuit Breakers

 

 

1 115 V 10 A AC Receptacle

 

 

Power is shared between duplex

 

 

receptacle and internal 14 socket

 

 

receptacle.

 

1

 

2

Circuit Breaker CB1

 

3

Circuit Breaker CB2

4

 

 

CB1 protects

duplex receptacle

 

 

 

 

and 115 volts ac portion of internal

2

3

14

socket

receptacle from

 

 

overload.

 

 

 

Press button to reset breaker.

 

 

CB2 protects 24 volts ac portion of

 

 

internal 14 socket receptacle from

 

 

overload.

 

 

 

Press button to reset breaker.

 

 

4

Circuit Breaker CB1

 

 

CB1 protects the motor control

 

 

circuitry from overload. If CB1 trips,

 

 

the wire drive motor is inoperative.

Press button to reset breaker.

802 748

OM-196 188 Page 14

Page 20
Image 20
Miller Electric Welder Weld Output Terminals And Selecting Cable Sizes, Volts AC Duplex Receptacle And Circuit Breakers