15-2. Setting Rise Time Parameter

NOTE

Maximum Rise Time setting will make the welding power source go to its maximum output in the maximum amount of time (1250 amperes per millisecond).

Access

Control

Display

1

 

 

 

 

> Rise Time

 

 

A/ms

Adaptive

 

 

 

AutoConfig

 

 

> 800

Retract

 

 

 

 

 

 

 

 

 

 

 

Increase/Decrease

1 Rise Time Display

Setting is depend on desired arc characteristics. Make a sample weld after each setting until desired arc characteristics are obtained.

Use Increase or Decrease button to change setting.

Range is 250 to 1250 amperes per millisecond (A/ms).

Press Mode Select button to go to next parameter or cycle power off and back on at power switch to sav- e setting and exit Control menu.

>Process Sequence SharpArc Card

>Prg 1 Pulse 035” Steel Argon – Oxy

Power

Switch A/ms

 

> 680

Or

Mode

Select

Go To

Section 15-4

15-3. Setting Adaptive Parameters

Access

Control

Display

Press Mode

Select

Rise Time

>Adaptive AutoConfig Retract

1

> Adapt A

Increase/

Decrease

1 Adaptive Parameter Display

Settings allow user to choose be- tween two adaptive programs, A or B.

Use Increase or Decrease button to change setting.

Press Mode Select button to go to next parameter or cycle power off and back on at power switch to sav- e setting and exit Control menu.

. For more detailed information

on A vs. B adaptive programs,

consult factory specialist.