Miller Electric Welder Setting Crater Sequence Display, Setting Retract Sequence Display

Models: Welder

1 132
Download 132 pages 16.6 Kb
Page 104
Image 104

11-6. Setting Crater Sequence Display

> Cratr

1

0.02 Sec

 

24.0 Volt

 

90 IPM

 

 

 

Parameter

Select

Cratr

 

Cratr

 

Cratr

> 0.12 Sec

 

0.12 Sec

 

0.12 Sec

24.0 Volt

 

> 18.0 Volt

 

18.0 Volt

90 IPM

 

90 IPM

 

> 200 IPM

Set Desired Time

Parameter

Set Desired

Parameter

Set Desired Wire

 

Select

Voltage

Select

Feed Speed

Increase/

 

Increase/

 

Increase/

Decrease

 

Decrease

 

Decrease

 

 

 

> Cratr

 

 

 

 

0.12 Sec

 

 

 

 

18.0 Volt

 

 

 

 

200 IPM

 

 

 

 

 

Parameter

 

 

 

 

Select

 

 

 

Increase

 

 

 

 

Proceed to next Section.

1 Crater Parameters Display

Parameter ranges are as follows:

Seconds, 0-2.50 Sec. If value set is zero (0), there is no Crater sequence.

Volts, 10.0-38.0 Volts.

Wire Feed Speed, 50 to 780 inches per minute, IPM.

Go to Section 11-7.

11-7. Setting Retract Sequence Display

>Rtrct

150 IPM

0.00 Sec

1

 

 

 

 

Rtrct

 

Rtrct

 

> 150 IPM

 

120 IPM

 

0.00 Sec

 

> 0.00 Sec

Parameter

Set Desired Speed

Parameter

Set Desired Time

 

Select

 

Select

 

 

 

 

 

 

Increase/

 

Increase/

 

Decrease

 

Decrease

> Rtrct

130 IPM

0.12 Sec

Parameter

Select

Increase

Proceed to next Section.

1Retract Parameter Display Parameter range is as follows:

Seconds, 0-1.00 seconds. If value set is zero (0), there is no Burnback sequence.

IPM 50-780 (1.3-19.8 mpm). Speed is program dependent.

Go to Section 11-8.

OM-196 188 Page 98