Miller Electric Welder operating instructions Arc Voltage Error Selection, Stick Check Selection

Models: Welder

1 132
Download 132 pages 16.6 Kb
Page 123
Image 123

14-19. Arc Voltage Error Selection

Access

Setup

Display

Press Mode

Select

Jog IPM

Flow

>Monitor Stick

.When a system reset is done, Monitor is set to Off.

1

Arc Volts

>On

2.0Volts

1.0Sec

Increase

Arc Volts

>Off

1 Monitor Display

Provides a means to enable/dis- able the arc voltage error feature and to set an acceptable range of deviation from set arc voltage or arc length (trim) before the error will ac- tuate.

When this feature is off, arc voltage or arc length variations will not cause an error or shut the unit down.

When this feature is on and a range of deviation is set (the range limits are ±0.1 to 9.9 volts from desired weld voltage, and ±0.1 to 9.9 sec- onds), arc voltage or arc length variations outside of the defined range, for a period of time exceed- ing the defined acceptable time pe- riod, cause either the error relay to energize or the unit to shut down depending on the Arc Start/Volt Sense shutdown error setting.

14-20. Stick Check Selection

Access

Setup

Display

Press Mode

Select

 

 

 

 

Flow

 

 

Stick

Monitor

 

 

Check

> Stick

 

 

> On

Ramps

 

 

 

 

 

 

 

 

 

 

 

1

Stick

Check

> Off

Increase

1 Stick Check Display

When stick check is On, a stick check routine is performed at the end of each weld. When Off, no stick check is done.

OM-196 188 Page 117

Page 123
Image 123
Miller Electric Welder operating instructions Arc Voltage Error Selection, Stick Check Selection