Miller Electric Welder operating instructions Voltmeter/Ammeter Help Displays, Help 1 Display

Models: Welder

1 132
Download 132 pages 16.6 Kb
Page 33
Image 33

5-4. Voltmeter/Ammeter Help Displays

.All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit.

1 Help 1 Display

Indicates a malfunction in the primary power circuit. If this display is shown, contact a Factory Authorized Service Agent.

2 Help 2 Display

Indicates a malfunction in the thermal protection circuitry located on the left side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

3 Help 3 Display

Indicates the left side of the unit has overheated. The unit has shut down to allow the fan to cool it (see Sec- tion 4-5). Operation will continue when the unit has cooled.

4 Help 4 Display

Indicates a malfunction in the thermal protection circuitry located on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent.

5 Help 5 Display

Indicates the right side of the unit has overheated. The unit has shut down to allow the fan to cool it (see Section 4-5). Operation will continue when the unit has cooled.

6 Help 6 Display

Indicates that the input voltage is too low and the unit has automatically shut down. Operation will continue when the voltage is within ±15% of the operating range. If this display is shown, have an electrician check the input voltage.

7 Help 7 Display

Indicates that the input voltage is too high and the unit has automatically shut down. Operation will continue when the voltage is within ±15% of the operating range. If this display is shown, have an electrician check the input voltage.

8 Help 8 Display

Indicates a malfunction in the sec- ondary power circuit of the unit. If this display is shown, contact a Factory Authorized Service Agent. In addition, when the optional ground current sensor is installed, this display indicates weld current in the ground conductor. When this occurs, have an electrician check the primary and secondary connections.

1

2

3

4

5

6

7

8

VA

HE.L P–1

VA

HE.L P–2

VA

HE.L P–3

VA

HE.L P–4

VA

HE.L P–5

VA

HE.L P–6

VA

HE.L P–7

VA

HE.L P–8

OM-196 188 Page 27

Page 33
Image 33
Miller Electric Welder operating instructions Voltmeter/Ammeter Help Displays, Help 1 Display