Miller Electric Welder Setting Teach Point Parameters For Pulse Welding Program

Models: Welder

1 132
Download 132 pages 16.6 Kb
Page 99
Image 99

10-4. Setting Teach Point Parameters For Pulse Welding Program

Increase/

Decrease

> Process

Sequence

Teach On

> 450 IPM

Teach On 450 IPM

Or

Teach On 450 IPM

SharpArc

Card

31.2 Vpk

343 Apk

>92 Abk

160 PPS

Parameter

Select

28.1 Vpk

340 Apk

Increase/

Decrease

31.2 Vpk

343 Apk

> 70 Abk

160 PPS

3

>28.1 Vpk

340 Apk

Parameter

Select

1

450 IPM

31.2 Vpk

> 343 Apk

70 Abk

Parameter

Select

>31.2 Vpk

340 Apk

Parameter

Select

Increase/

Decrease

450IPM 31.2 Vpk

> 340 Apk

70 Abk

2

31.2 Vpk

343 Apk

92 Abk

>160 PPS

4

Increase/ Decrease

6

31.2 Vpk

343 Apk

92 Abk

>280 PPS

Prg 1

C

Pulse

 

035” Steel Argon – Oxy

343 Apk

92 Abk

280 PPS

> 1.9 PWms

Parameter

Select

5

Pulse

035” Steel

Argon – Oxy

> Teach Off

Parameter

Select

Increase/

Decrease

Increase/ Decrease

Wait for 5 seconds

343Apk

92Abk

280PPS

>3.6 PWms

Parameter

Select

>Teach On 450 IPM 31.2 Vpk 343 Apk

When the Process Teach mode is On, and one of the following pulse parameters is se- lected: Apk, Abk, PPS, PWms, or Vpk, the pulse panel displays the selected pulse pa- rameter instead of Trim (arc length). When the pulse parameter is selected, the value can be changed with the pulse panel controls as follows:

1 Vpk Display

2Apk Display

3Abk Display

4PPS Display

5PWms Display

When values have been set for a teach point, strike and maintain an arc for five seconds. Repeat procedure at each teach point until custom program is complete (see Section 10-2).

Turn Teach mode Off.

6 Custom Pulse Screen

The letter C will appear in the upper right corner of all customized programs.

Customized programs can be reverted back to factory-set values through memory reset (see Section 14-12).

OM-196 188 Page 93

Page 99
Image 99
Miller Electric Welder operating instructions Setting Teach Point Parameters For Pulse Welding Program