14-17. Jog Wire Feed Speed Selection

Access

Setup

Display

Press Mode

Select

Name

Program

>Jog IPM Flow

Robot Jog

>Remote Local Jog 200 ipm

1

Robot Jog

>local Local Jog 200 ipm

Increase

Parameter

1 Jog IPM Display

Jog wire feed speed can be varied between 50 and 780 inches per minute, IPM.

When not welding, a Robot Jog local setting will jog wire at the Local Jog ipm setting, even if robot pro- vides wire jog signal.

A Robot Jog remote setting requires that the robot provide a jog command and jog speed signal.

Auxiliary jog connections at the peripheral receptacle and front panel jog push buttons will jog wire at the Local Jog ipm setting even if Robot Jog is set for remote.

Parameter

Select

Robot Jog local Local Jog

> 425 ipm

Select

Robot Jog local

Local Jog

> 200 ipm

Increase/

Decrease

14-18. Flow Selection

Access

Setup

Display

Press Mode

Select

Program

Jog IPM

>Flow Monitor

.When a system reset is done, Flow is set to Off.

1

Detect

Flow >Off

Increase

Detect

Flow

>On

1 Flow Display

 

 

Provides

a

means

to

enable/disable the

flow switch

input.

 

 

 

When this

feature

is off,

no

monitoring is done for a flow switch input signal.

When this feature is on, the flow detect input monitors flow switch signal and will cause an error if flow is not present.

OM-196 188 Page 116

Page 122
Image 122
Miller Electric Welder operating instructions Jog Wire Feed Speed Selection, Flow Selection