Miller Electric Welder Selecting Program Name Feature, Remote Program Select

Models: Welder

1 132
Download 132 pages 16.6 Kb
Page 121
Image 121

14-14. Selecting Program Name Feature

Access

Setup

Display

Press Mode

Select

Memory

Shutdown

>Name Program

Card Programs

>On

1

Card

Programs

> Off

Increase

1 Name Display

When a data card is used, the pro- grams written from the unit to the card can be named.

14-15. Remote Program Select

Access

Setup

Display

Press Mode

Select

 

 

 

 

Shutdown

 

 

Remote

Name

 

 

Select

> Program

 

 

> Off

Jog IPM

 

 

 

 

 

 

 

 

 

 

 

1

Remote

Select

> On

Increase

1 Program Display

When Program is On, a remote device or robot Teach Pendant may be used to select programs (see Section 14-16). When Off, program selection must be done from Setup Pendant.

14-16. Remote Program Setting

NOTE

When Remote Program Select is “On”, program selection will be determined by remote input once a weld is intiated. In “Standby” mode, program selection can be done in a normal manner from the Setup Pendant.

See the following table for the remote program select binary code.

Program No.

Output A

Output B

Output C

 

 

 

 

1

Off

Off

Off

 

 

 

 

2

On

Off

Off

 

 

 

 

3

Off

On

Off

 

 

 

 

4

On

On

Off

 

 

 

 

5

Off

Off

On

 

 

 

 

6

On

Off

On

 

 

 

 

7

Off

On

On

 

 

 

 

8

On

On

On

 

 

 

 

OM-196 188 Page 115

Page 121
Image 121
Miller Electric Welder operating instructions Selecting Program Name Feature, Remote Program Select, Remote Program Setting