9-3. Setting Weld Sequence Display

Set Desired Weld

Sequence Trim

Increase/

Decrease

Set Desired Weld Sequence

Wire Feed Speed

Increase/

Decrease

Weld

>50 Trim

200 IPM

Parameter

Select

Weld

60 Trim

>200 IPM

Parameter

Select

1

1 Weld Parameters Display

Parameter ranges are as follows:

 

 

Trim (Arc Length), 0-99

 

Wire Feed Speed, 50-780 Inches

 

Per Minute, IPM

 

Go to Section 9-4.

>Weld

60 Trim

300 IPM

Increase

Proceed to next Section.

9-4. Setting Crater Sequence Display

1

>Cratr

0.00Sec

50 Trim

200 IPM

Cratr

>0.00 Sec

50 Trim

200 IPM

Parameter

Set Desired

Time

Select

 

Increase/

Decrease

Parameter

Select

1 Crater Parameters Display

Parameter ranges are as follows:

Seconds, 0-2.50 Sec. If value set is zero (0), there is no Crater sequence.

Trim (Arc Length), 0-99

Wire Feed Speed, 50-780 Inches Per Minute, IPM

Go to Section 9-5.

> Cratr

Cratr

0.20 Sec

0.20 Sec

60 Trim

60 Trim

150 IPM

> 150 IPM

Parameter

Set Desired Wire

Select

Feed Speed

Increase

Proceed to next Section.Increase/ Decrease

Cratr

0.20 Sec

>50 Trim

200 IPM

Parameter

Set Desired

Select

Trim

Increase/

Decrease

OM-196 188 Page 89

Page 95
Image 95
Miller Electric Welder operating instructions Setting Weld Sequence Display, Setting Crater Sequence Display