4-4. Upper Front Panel Controls

8

1

2

3

4

5

6

7

1 Setup Pendant Receptacle

Receptacle for connecting pendant interconnecting cord.

2Jog Forward Push Button Advances wire out of the gun.

3Wirefeed Indicator LED

LED lights when wire feed motor is energized.

4

Jog Reverse Push Button

7

Contactor Indicator LED

Retracts wire up into the gun.

LED lights when welding power source

5

Gas Indicator LED

contactor is energized.

LED lights when gas solenoid is energized.

8

Main Display

6

Purge Push Button

 

 

Momentarily energizes gas solenoid to

Shows system state, active program, error

purge air from gun shielding gas line, or to

messages, weld parameters at idle and

adjust shielding gas regulator.

during welding.

184 197

OM-196 188 Page 22

Page 28
Image 28
Miller Electric Welder operating instructions Upper Front Panel Controls