5 - 7
5. PARAMETERS
(2) Auto tuning response (parameter No.PA09)
If the machine hunts or generates large gear so und, decrease the set value. To improve performanc e, e.g.
shorten the settling time, increase the set val ue.
Setting Response Guideline for machine
resonance frequency [Hz] Setting Response Guideline for machine
resonance frequency [Hz]
1 Low response 10.0 17 Low response 67.1
2 11.3 18 75.6
3 12.7 19 85.2
4 14.3 20 95.9
5 16.1 21 108.0
6 18.1 22 121.7
7 20.4 23 137.1
8 23.0 24 154.4
9 25.9 25 173.9
10 29.2 26 195.9
11 32.9 27 220.6
12 37.0 28 248.5
13 41.7 29 279.9
14 47.0 30 315.3
15 52.9 31
355.1
16 Middle response 59.6 32 Middle response 400.0
5.1.7 In-position range
Parameter
No. Symbol Name Initial value Unit Setting range
PA10 INP In-position range 100 pulse 0 to 65535
POINT
This parameter cannot be used in the speed control mode.
Set the range, where in position (INP) is output , in the command pulse unit.
Servo motor droop pulse
In-position range [pulse]
Command pulse
Command pulse
Droop pulse
In position (INP)
ON