13 - 88
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
13.9.9 EMC filter (recommended)
For compliance with the EMC directive of the EN Stand ard, it is recommended to use the following filter. Some
EMC filters are large in leakage current.
(1) Converter unit Drive unit
Recommended filter
(Soshin Electric)
Converter unit Drive unit
Model Leakage current
[mA]
Mass [kg]
MR-J3-CR55K MR-J3-DU30KB MR-J3-DU37KB HF3200A-UN 9 18
MR-J3-CR55K4 MR-J3-DU30KB4 to MR-J3-DU55KB4 TF3150C-TX 5.5 31
(2) Connection example
1
2
3
4
5
6
E
NFB
(Note)
Power supply
L1
L2
L3
L11
L21
Converter unit
MC
Drive unit
L11
L21
EMC filter
Note. For power supply specifications, refer to section 13.1.3.