11 - 51
11. OPTIONS AND AUXILIARY EQUIPMENT
(b) 400V class
P1
(Note 8)
Stepdown
transformer DOCOM
RA1
EM1
C
B
R/L11
3-phase
380 to
480VAC
S/L21
T/L31
R2/L1
S2/L22
R2/L12
T2/L32
S2/L2
(Note 3)
P24
SD
RDYB
RDYA
RSO
SE
A
T2/L3
R/L11
S/L21
T/MC1
RES
SD
(Note 1)
L11
L21
P( )
N( )
U
V
W
(Note 1)
EM1
(Note 2)
RA1
RA2
24VDC
power
supply
Thermal
relay OHS2
OHS1
CN2

MC

NF FR-CVL FR-CV-H

MC
RA1 RA2 EM1 OFF ON
RESET
SK
MC
(Note 1)
Servo motorServo amplifier
(Note 4)
Servo system
controller
(Note 5)
(Note 1)
(Note 7)
DICOM
N/L
P/L
U
V
W
(Note 6)

Note 1. Configure a sequence that will shut off main circuit power at an emergency stop or at FR-CV-H or servo amplifier alarm

occurrence.

2. For the servo motor with thermal relay, configure a sequence that will shut off main circuit power when the thermal relay

operates.

3. For the servo amplifier, configure a sequence that will switch the servo on after the FR-CV-H is ready.

4. For the FR-CV-H, the RSO signal turns off when it is put in a ready-to-operate status where the reset signal is input.

Configure a sequence that will make the servo inoperative when the RSO signal is on.

5. Configure a sequence that will make a stop with the emergency stop input of the servo system controller if an alarm occurs

in the FR-CV-H. When the servo system controller does not have an emergency stop input, use the forced stop input of the

servo amplifier to make a stop as shown in the diagram.

6. When using the servo amplifier of 7kW or less, make sure to disconnect the wiring of built-in regenerat ive resistor (2kW or

less: P and D, 3.5k to 7kW: P and C).

7. When using the servo amplifier of 11k to 22kW, make sure to connect P1 and P( ). (Factory-wired.)

8. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class servo am plifiers.