2 - 1
2. INSTALLATION 2. INSTALLATION
CAUTION
Stacking in excess of the limited number of pr oducts is not allowed.
Install the equipment on incombustible materia l. Installing them directly or close to
combustibles will lead to a fire.
Install the equipment in a load-bearing place in accordance with this Instruction
Manual.
Do not get on or put heavy load on the equipment to prevent injury.
Use the equipment within the specified environmental condition range. (For the
environmental conditions, refer to section 1 .3.)
Provide an adequate protection to prevent screws, metallic de tritus and other
conductive matter or oil and other combustible m atter from entering the servo
amplifier.
Do not block the intake/exhaust ports of the ser vo amplifier. Otherwise, a fault may
occur.
Do not subject the servo amplifier to drop im pact or shock loads as they are
precision equipment.
Do not install or operate a faulty servo amplifier.
When the product has been stored for an extende d period of time, consult
Mitsubishi.
When treating the servo amplifier, be carefu l about the edged parts such as the
corners of the servo amplifier.
2.1 Installation direction and clearances
CAUTION
The equipment must be installed in the specified dir ection. Otherwise, a fault may
occur.
Leave specified clearances between the servo amplifier and control box inside
walls or other equipment.
(1) 7kW or less
(a) Installation of one servo amplifier
40mm
or more
Servo amplifier
40mm
or more
Control box
10mm
or more
10mm
or more
Wiring allowance
80mm Top
Bottom
Control box