13 - 29
13. SERVO AMPLIFIERS WITH A LARGE CAPACITY (30k TO 55kW)
(2) When magnetic contactor control connector (CNP1) is made invalid POINT The converter unit controls the main circuit magnetic contactor. When making CNP1 invalid, set "0000" in parameter No.PA02. (Refer to section 13.5.) Always connect a protection coordination cable (MR-J3CDL05M) and a termination connector (MR-J3-TM). When they are not connected properl y, the servo-on may not be turned ON. For the control power supplies of the converter unit and the drive unit, al ways turn ON or OFF at the same time. (a) 200V class (MR-J3-DU30KB MR-J3-DU37KB)
(Note 5)
Power
supply
Regenerative
option(Note 1)
Regenerative
option(Note 1)
Regenerative
option(Note 1)
MC
(Note 3)
Termination
connector
MR-J3-TM
(Option)
L
L
MR-J3CDL05M
cable
Converter unit Drive unit
L1
L2
L3
L11
L21
NFB
1MC1
2MC2
CN40 CN40A
CN2
Dynamic
brake
(Option)
Servo
motor
thermal
relay
OHS1
BW
BV
BU
M
OHS2
V
U
W
CN40B
24VDC
power supply
V
U
W
Servo motor
NFB
TE2-2
L
L
TE2-1
C
P1
P2
Power factor improving
DC reactor (Option)
(Note 2)
L11
L21
G4G3
PC
G4G3
PC
SR
G4G3
PC
Cooling fan Cooling fan Cooling fan
SRSR
CNP1 CN1
1DICOM
5DOCOM
6DICOM
RA22ALM
7EM1
9DOCOM
CN3
EM1
3
20
SDPlate
DICOM
10
ALM15
DOCOM
5DICOM
RA1
RA3RA1 RA2 EM1
SK
Converter
unit
Motor
thermal relay
Operation
-ready
Drive
unit
RA4
Controller
forced stop
(Note 3)
Forced stop
MC
Cooling fan
Encoder cable
(Note 3)
24VDC
24VDC
3-phase
200 to 230VAC
50/60Hz
Encoder
OFF ON
MC
MC
SK
(Note 4)
RA3

Note 1. For the MR-RB137. For the MR-RB137, three units are used as one set (permissible wattage: 3900W).

2. When using the Power factor improving DC reactor, disconnect the short bar across P1-P2.

3. Make up a sequence that turns off the drive unit forced stop (EM1) and the converter unit forced s top (EM1) at the same time.

4. Attach connector for magnetic contactor control (CNP1) on the converter unit. Unattached state may cause an electric shock.

5. For specifications of cooling fan power supply, refer to section 13.3.8.