10.2 Power supply equipment capacity and generated loss
(1) Amount of heat generated by the servo am plifier
Table 10.1 indicates servo amplifiers' power s upply capacities and losses generated under rated load. For
thermal design of an enclosure, use the values in Table 10.1 in cons ideration for the worst operating
conditions. The actual amount of generated heat will be in termediate between values at rated torque and
servo off according to the duty used dur ing operation. When the servo motor is run at less than the
maximum speed, the power supply capacity will be smaller than the val ue in the table, but the servo
amplifier's generated heat will not change.
Table 10.1 Power supply capacity and generated heat per servo am plifier at rated output
(Note 2)
Servo amplifier-generated heat[W]
Area required for
heat dissipation
Servo amplifier Servo motor
(Note 1)
Power supply
capacity[kVA] At rated torque With servo off [m2]
HF-MP053 0.3 25 15 0.5
HF-MP13 0.3 25 15 0.5
MR-J3-10B (1)
HF-KP053 13 0.3 25 15 0.5
HF-MP23 0.5 25 15 0.5
MR-J3-20B (1) HF-KP23 0.5 25 15 0.5
HF-MP43 0.9 35 15 0.7
MR-J3-40B (1) HF-KP43 0.9 35 15 0.7
HF-SP52 (4) 1.0 40 15 0.8
HF-SP51 1.0 40 15 0. 8
MR-J3-60B (4)
HC-LP52 1.0 40 15 0.8
HF-MP73 1.3 50 15 1.0
HF-KP73 1.3 50 15 1. 0
MR-J3-70B
HC-UP72 1.3 50 15 1.0
HF-SP102 (4) 1.7 50 15 1.0
HF-SP81 1.5 50 15 1. 0
MR-J3-100B (4)
HC-LP102 1.7 50 15 1.0
HF-SP152 (4) 2.5 90 20 1.8
HF-SP202 (4) 3.5 90 20 1.8
HF-SP121 2.1 90 20 1.8
HF-SP201 3.5 90 20 1.8
HC-RP103 1.8 50 15 1.0
HC-RP153 2.5 90 20 1.8
HC-UP152 2.5 90 20 1.8
MR-J3-200B (4)
HC-LP152 2.5 90 20 1.8
HF-SP352 (4) 5.5 130 20 (25) (Note 3) 2.7
HC-RP203 3.5 90 20 1.8
HC-UP202 3.5 90 20 1.8
HC-LP202 3.5 90 20 1.8
MR-J3-350B (4)
HF-SP301 4.8 120 20 2.4
HF-SP502 (4) 7.5 195 25 3.9
HC-RP353 5.5 135 25 2.7
HC-RP503 7.5 195 25 3.9
HC-UP352 5.5 195 25 3.9
HC-UP502 7.5 195 25 3.9
HC-LP302 4.5 120 25 2.4
HA-LP502 7.5 195 25 3.9
MR-J3-500B (4)
HF-SP421 6.7 160 25 3.2