1 - 26
1. FUNCTIONS AND CONFIGURATION
(5) MR-J3-350B4 MR-J3-500B(4)
R S T
L21 P1
P2
CN3
CN2
CN1A
CN1B
CN4
CN5
(Note 2)
L11
UVW
CP
L1
L2
L3
Regenerative option
Line noise filter
(FR-BLF)
(Note 3)
Power supply
Magnetic
contactor
(MC)
No-fuse breaker
(NFB) or fuse
MR Configurator
Personal
computer
Servo amplifier
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-(H))
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
(Note 1)
Battery
MR-J3BAT
Servo motor
Junction
terminal
block
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P1 and P2.
3. Refer to section 1.3 for the power supply specification.