11 - 46
11. OPTIONS AND AUXILIARY EQUIPMENT
(2) Connection example
NFB MC
Servo amplifier
L11
L21
L1
L2
L3
SK
ON
MC
BC
NPC
RDY
SE
Alarm
output
RDY
output
A
B
C
5m or less
Operation ready
MC
OFF
EMG
ALM
RA2
FR-RC-(H)
Ready
Power factor improving reactor
FR-BAL-(H)
R/L1
S/L2
T/L3
B
C
RRX
R
SX
S
TX
T
Phase detection
terminals
(Note 1)
Power regeneration
converter FR-RC-(H)
N/ P/
EM1
RA
DOCOM
DICOM
ALM Trouble(Note 3)
DOCOM
Forced stop
24VDC
P2
P1
(Note 4)
(Note 2)
CN3 CN3
(Note 5)
(Note 6)
Power supply

Note 1. When not using the phase detection terminals, fit the jumpers across RX-R, SX-S and TX-T. If the jumpers remain

removed, the FR-RC-(H) will not operate.

2. When using servo amplifiers of 5kW and 7kW, always remove the lead of built-in regenerative resistor connected

to P terminal and C terminal.

3. When setting not to output Trouble (ALM) with parameter change, configure power supply circuit for turning

magnetic contactor off after detecting an occurrence of alarm on the controller side.

4. Always connect P1-P2 (For 11k to 22kW, connect P1-P). (Factory-wired.) When using the power factor improving

DC reactor, refer to section 11.13.

5. Stepdown transformer is required for coil voltage of magnetic contactor more than 200V class in 400V class servo

amplifiers.

6. Refer to section 1.3 for the power supply specification.