1. FUNCTIONS AND CONFIGURATION
1.3 Servo amplifier standard specifications (1) 200V class, 100V class Servo amplifier
MR-J3-
Item
10B 20B 40B 60B 70B 100B 200B 350B 500B 700B 11KB15KB 22KB 10B1 20B1 40B1
Voltage/frequency 3-phase or 1-phase 200
to 230VAC, 50/60Hz 3-phase 200 to 230VAC, 50/60Hz 1-phase 100V to
120VAC, 50/60Hz
Permissible voltage fluctuation
3-phase or 1-phase 200
to 230VAC: 170 to
253VAC
3-phase 170 to 253VAC 1-phase 85 to
132VAC
Permissible frequency fluctuation Within 5%
Power supply capacity Refer to section 10.2
Power suppl
y
Inrush current Refer to section 10.5
Voltage,
frequency 1-phase 200 to 230VAC, 50/60Hz 1-phase 100 to
120VAC, 50/60Hz
Permissible
voltage
fluctuation
1-phase 170 to 253VAC 1-phase 85 to
132VAC
Permissible
frequency
fluctuation
Within 5%
Input 30W 45W 30W
Control circuit
power supply
Inrush current Refer to section 10.5
Voltage 24VDC 10%
Interface power
supply Power supply
capacity (Note 1) 150mA or more
Control System Sine-wave PWM control, current control system
Dynamic brake Built-in External option Built-in
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal relay),
servo motor overheat protection, encoder error protection, regenerative error protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection.
Structure Self-cooled, open
(IP00) Force-cooling, open (IP00) Self-cooled, open
(IP00)
[] (Note 2) 0 to 55 (no n-freezing) In
operation [] 32 to 131 (non-freezing)
[] 20 to 65 (non-fr eezing)
Ambient
temperature In storage [] 4 to 149 (non-freezing)
In operation Ambient
humidity In storage 90%RH or less (non-condensing)
Ambient Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude Max. 1000m above sea level
Environmen
t
Vibration 5.9 [m/s2] or less
[kg] 0.8 0.8 1.0 1.0 1.4 1.4 2.1 2.3 4.6 6.2 18 18 19 0.8 0.8 1.0
Mass [lb] 1.76 1.76 2.21 2.213.09 3.09 4.63 5.07 10.1 13.7 39.7 39.7 41.9 1.76 1.76 2.21
Note 1. 150mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifier of 3.5kW or less, operate them at the ambient temperatures of 0 to 45 or at 75% or
smaller effective load ratio.