10 - 2
10. CHARACTERISTICS
10000
1000
100
10
1
0 100 200 300
During operation
During servo lock
Operation time [s]
(Note) Load ratio [%]
MR-J3-11KB(4) to MR-J3-22KB(4)
Note. If operation that generates torque more than 100% of the rating is performed with an abnormally high frequency in a servo motor
stop status (servo lock status) or in a 30r/min or less low-speed operation status, the servo amplifier may fail even when the
electronic thermal relay protection is not activated.
Fig 10.1 Electronic thermal relay protection characteristics