11 - 21

11. OPTIONS AND AUXILIARY EQUIPMENT

11.2 Regenerative options

CAUTION The specified combinations of regenerative options and servo amplifiers may only

be used. Otherwise, a fire may occur.

(1) Combination and regenerative power

The power values in the table are resistor-gen erated powers and not rated powers.

Regenerative power[W]
Servo amplifier Built-in
regenerative
resistor
MR-RB032
[40 ]
MR-RB12
[40 ]
MR-RB30
[13 ]
MR-RB31
[6.7 ]
MR-RB32
[40 ]
(Note 1)
MR-RB50
[13 ]
(Note 1)
MR-MB51
[6.7 ]
MR-J3-10B (1) 30
MR-J3-20B (1) 10 30 100
MR-J3-40B (1) 10 30 100
MR-J3-60B 10 30 100
MR-J3-70B 20 30 100 300
MR-J3-100B 20 30 100 300
MR-J3-200B 100 300 500
MR-J3-350B 100 300 500
MR-J3-500B 130 300 500
MR-J3-700B 170 300 500

Regenerative power[W]
Servo amplifier Built-in
regenerative
resistor
MR-RB1H-4
[82 ]
(Note 1)
MR-RB3M-4
[120 ]
(Note 1)
MR-RB3G-4
[47 ]
(Note 1)
MR-RB5G-4
[47 ]
(Note 1)
MR-RB34-4
[26 ]
(Note 1)
MR-RB54-4
[26 ]
MR-J3-60B4 15 100 300
MR-J3-100B4 15 100 300
MR-J3-200B4 100 300 500
MR-J3-350B4 100 300 500
MR-J3-500B4 130 300 500
MR-J3-700B4 170 300 500

(Note 2) Regenerative power[W]
Servo amplifier External regenerative
resistor (Accessory)
MR-RB5E
[6 ]
MR-RB9P
[4.5 ]
MR-RB9F
[3 ]
MR-RB6B-4
[20 ]
MR-RB60-4
[12.5 ]
MR-RB6K-4
[10 ]
MR-J3-11KB 500 (800) 500 (800)
MR-J3-15KB 850 (1300) 850 (1300)
MR-J3-22KB 850 (1300) 850 (1300)
MR-J3-11KB4 500 (800) 500 (800)
MR-J3-15KB4 850 (1300) 850 (1300)
MR-J3-22KB4 850 (1300) 850 (1300)
Note 1. Always install a cooling fan.