MultiModemBA User Guide

Xn

n = 0,1,2,3 or 4

* X0 selects Basic Result Codes (w/o CONNECT

 

 

1200, CONNECT 2400).

 

 

X1 selects Extended Result Codes (w/CONNECT

 

 

1200, CONNECT 2400).

 

 

X2 selects Standard AT Command set with NO

 

 

DIAL TONE.

 

 

X3 selects Standard AT Command set with BUSY.

 

 

X4 selects Standard AT Command set with NO

 

 

DIAL TONE and BUSY.

#Xn

n= 0 or 1

* #X0 selects single XOFF character sent until XON

 

 

level returns.

 

 

#X1 selects multiple XOFF characters after buffer

 

 

level is full.

Yn

n = 0 or 1

* Y0 disables sending or responding to long space

 

 

“break”.

 

 

Y1 enables sending or responding to long space

 

 

“breaks”.

Z

 

All configuration parameters are reset to default

 

 

values.

,

In Dial Command

Causes pause during dialing.

;

In Dial Command

Causes return to Command Mode after dialing.

!

In Dial Command

Causes modem to flash On-Hook.

@

In Dial Command

Causes modem to wait for ringback, then 5 seconds

 

 

of silence before processing next part of command.

+++AT<CR>

 

In-band Escape Sequence. Places modem in

 

 

Command Mode while still remaining On-Line. Enter

 

 

+++ followed by the letters A and T, up to ten

 

 

command characters, and a RETURN.

BREAK AT<CR>

 

Out-of-band Escape Sequence. Places modem in

 

 

Command mode while still remaining On- Line.

 

 

Enter a BREAK signal, followed by the letters A and

 

 

T, up to sixty command characters, and hit

 

 

RETURN.

* Factory Default Setting