Chapter 6 - Callback Security and Remote Configuration

7.Enter your modem's LOGIN Password (as selected in Table 6-1) by entering: AT#Ixxxxxxxxxx<CR> (xxxxxxxxxx from Table 6-1)

8.Enter your modem's Setup Password (as selected in Table 6-1) by entering: AT#Syyyyyyyyyy<CR> (yyyyyyyyyy from Table 6-1)

Table 6-3. Callback Operational Sequence Procedures

Perform the following steps when dialing into a dialback modem:

StepProcedure

1.When called, the modem answers and after a slight delay, responds with: Password>

2.Enter your modem's LOGIN Password (Table 6-1) and hit RETURN. If entered correctly, the modem responds with:

DB>

3.Enter the Callback Password corresponding to the phone number you wish called back and hit RETURN (Callback Passwords and phone numbers entered in Table 6-2). You can also use special characters + and -. They must have been entered as part of the Callback phone numbers in Step 5 of Table 6-2. If you use the - character along with your password, the Callback modem will connect directly without hanging-up and calling back. If you use the + character along with your password, you can also enter a phone number which you wish the Callback modem to dial after hanging-up. The + and - characters must be entered after the Dial-back password, (i.e., DB>xxxxxx+). This is also the point where you enter an extension number if your Callback number used the ??? feature (Step 5 in Table 6-2).

You have three tries at each prompt to enter the information properly, with an incorrect entry resulting in a password retry. You must enter the requested information correctly within one minute or the Callback modem will hang-up. When the information is entered properly, the called modem will hang-up and after a 15 second delay, call you back. When your modem answers, the dialback modem will respond with the following:

Password>

4.Enter the modem's LOGIN Password again (the same as in Step 1). The Callback modem responds with:

CONNECT

You are now in Data Mode.

6.3.2Remote Configuration Procedures

The procedures for using the Remote Configuration features are the same whether or not a call originates from the remote modem. Once the modem is on-line, perform the procedures in Table 6-4.

Table 6-4 Remote Configuration Operation Procedures

StepProcedure

1.Remote Escape Configuration requires %%%AT<CR> to be sent if the default value in S- Register S13 has not been changed.

The modem responds with:

1.- DATA Mode

2.- COMMAND Mode

61

Page 61
Image 61
Multi-Tech Systems BA-Series manual Remote Configuration Procedures, Callback Security and Remote Configuration