Appendices

S4= 0-127

S4 holds the decimal value of the character recognized as a line feed (asynchronous operation only). The line feed control character is output after the carriage return control character, if verbose result codes are enabled. The factory default is 010.

S5= 0-127

S5 holds the decimal value of the character recognized as a backspace (asynchronous operation only). The modem will not recognize the backspace character if this register is set to a value greater than 32. The factory default is 008.

S6 = 0-255

S6 sets the length of time, in seconds, that the modem must wait (minimum 2 seconds even if the value is less than 2) after going off-hook before dialing the first digit of the telephone number The factory default is 002.

S7=1-255 for international version. The factory default is 060.

S7=0-58for Japan version. The factory default is 058.

Set the time, in seconds, that the modem must wait before hanging up because carrier is not detected.

S8= 0-255

S8 sets the time, in seconds, that the modem must pause when the “,” dial modifier is encountered in the dial string. The factory default is 002.