Configuring SNMP 335
/cfg/sys/adm/snmp/event
followed by:
addmonitor [ <options>
] -x <name> <OID>
[present|absent| changed]
Adds an existence monitor and trigger as
defined in the DISMAN-EVENT-MIB.
Valid <options> are:
-c <comment>—adds a comment
-f <frequency>—the sampling
interval, in seconds. The default is 600
(10 minutes).
-o <OID>—additional objects to send
in the event
-e <EventName>—the name of a
notification event
-d <OID>—the delta discontinuity OID
-D timeTicks|timeStamp|dateAnd
Time—the delta discontinuity type
Other parameters are:
name—a unique name you assign to
the monitor, for identification
OID—the object identifier (or symbolic
name) to monitor
present|absent|changed—indicate
s whether the object being monitored is
present, absent, or has changed
delmonitor <name> Removes the specified monitor from the
configuration.
addevent [-c <comment> ]
<name> <notification> [
<OID...> ]
Adds a notification event as defined in the
DISMAN-EVENT-MIB.
��-c <comment>—adds a comment
(optional)
name—a unique name you assign to
the event, for identification
notification—the OID (or symbolic
name) of the notification
OID...—additional notification OIDs
(optional)
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008
Copyright © 2007,2008 NortelNetworks
.