Managing network access devices 61
ATTENTION
Based on the discovery result, the wizard asks for switch ports, switch
uplinks port (in case of sscplite switch) or NSNA communication port
(in case of sscp switch).
5Specify the VLAN ID of the Red VLAN, as configured on the
network access devices. The network access devices in the
domain can share a common Red VLAN or can each have a
separate Red VLAN.
Red vlan id of Switch: <VLAN ID>
6Specify the type of switch. Valid options are:
ERS8300 (for an Ethernet Routing Switch 8300), ERS5500 or
ERS55 (for an Ethernet Routing Switch 5510, 5520, or 5530),
and ERS4500.
The default is ERS8300.
ATTENTION
The input is case sensitive.
Enter the type of the switch (ERS8300/ERS5500/ERS4500)
[ERS8300]:
7Specify the TCP port for communication between the Nortel
SNAS and the network access devices. The default is port 5000.
NSNA communication port[5000]:
8The SSH fingerprint of the switch is automatically picked up if the
switch is reachable. If the fingerprint is successfully retrieved,
go to step 7.
If the fingerprint is not successfully retrieved, you will receive an
error message and be prompted to add the SSH key.
Trying to retrieve fingerprint...failed.
Error: "Failed to retrieve host key"
Do you want to add ssh key? (yes/no) [no]:
Choose one of the following:
aTo paste in a public key you have downloaded from the
switch, enter Yes.Gotostep6.
bTo continue adding the switch to the configuration without
adding its public SSH key at this time, press Enter to accept
the default value (no). After you have added the switch, add
or import the SSH public key for the switch (see “Managing
SSH keys for Nortel SNAS communication” (page 71)).
Go to step 7.
9To add the switch public key:
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008
Copyright © 2007,2008 NortelNetworks
.