454 Syslog messages
Table 75 "System control process messages—INFO" (page 454) lists the
System Control Process INFO messages.
Table 75
System control process messages—INFO
Message Category Explanation/Action
System started [isdssl-<version>] INFO Sent whenever the system control process has
been (re)started.

About alarm messages

Alarms are sent at a syslog level corresponding to the alarm severity
shown in Table 76 "Alarm severity and syslog level correspondence" (page
454).
Table 76
Alarm severity and syslog level correspondence
Alarm severity Syslog level
CRITICAL ALERT
MAJOR CRITICAL
MINOR ERROR
WARNING WARNING
* ERROR
Alarms are formatted according to the following pattern:
Id: <alarm sequence number>
Severity: <severity>
Name: <name of alarm>
Time. <date and time of the alarm>
Sender: <sender, e.g. system or the Nortel SNAS device’s IP address>
Cause: <cause of the alarm>
Extra: <additional information about the alarm>
When an alarm is cleared, one of the following messages is sent:
Alarm Cleared Name="<Name>" Id= "<ID>" Sender="<Sender>"
Alarm Cleared Id="<ID>"
Table 77 "System Control Process messages—ALARM" (page 455) lists
the System Control Process ALARM messages. To simplify finding the
alarm messages, the name parameter is listed first.
Nortel Secure Network Access Switch
Using the Command Line Interface
NN47230-100 03.01 Standard
28 July 2008
Copyright © 2007,2008 NortelNetworks
.