Filters and QoS Configuration for ERS 5500

 

 

Technical Configuration Guide

v2.0

NN48500-559

Commit Rate: 10000 Kbps

Commit Burst: 524288 Bytes

In-Profile Action: Standard_Service

Out-Profile Action: Drop_Traffic

Session Id: 0

Storage Type: NonVolatile

Id: 2

Name: m2

Commit Rate: 5000 Kbps

Commit Burst: 524288 Bytes

In-Profile Action: Standard_Service

Out-Profile Action: Drop_Traffic

Session Id: 0

Storage Type: NonVolatile

Id: 3

Name: m3

Commit Rate: 1000 Kbps

Commit Burst: 524288 Bytes

In-Profile Action: Standard_Service

Out-Profile Action: Drop_Traffic

Session Id: 0

Storage Type: NonVolatile

Step 3 – Verify that the Classifier Block with the correct classifier and meter number

ERS5500-24T#show qos classifier-block

Result:

Id: 1

Block Name: b1

Block Number: 1

Classifier Name: c1

Classifier Set Id: 1

Meter Name: m1

Meter Id: 1

Action Name:

Action Id:

Session Id: 0

Storage Type: NonVolatile

Id: 2

Block Name: b1

Block Number: 1

Classifier Name: c2

Classifier Set Id: 2

Meter Name: m2

Meter Id: 2

Action Name:

Action Id:

Session Id: 0

Storage Type: NonVolatile

Id: 3

Block Name: b1

Block Number: 1

Classifier Name: c3

Classifier Set Id: 3

Meter Name: m3

Meter Id: 3

Action Name:

Action Id:

Session Id: 0

Storage Type: NonVolatile

___________________________________________________________________________________________________________________________

Nortel Confidential Information Copyright © 2008 Nortel Networks. All Rights Reserved.

 

External Distribution

48

Page 49
Image 49
Nortel Networks 5530, 5520, 5510 manual ERS5500-24T#show qos classifier-block