Filters and QoS Configuration for ERS 5500 |
|
|
Technical Configuration Guide | v2.0 |
|
12.6 Configuration Example 5 – L2 and L3 Classification
In this configuration example, the Ethernet Routing Switch is used as L2 switch with two VLANs providing L2 private VLAN services. Both VLAN’s have the same
•Setup a policy to provide Gold service for host 1 and Silver service for host 2
•For all other
Figure 8: L2 and L3 Classification Example
The best way to accomplish these tasks is to:
•Create a Role Combination for port 1/3
•Create the first classifiers element with host 1’s IP address and VLAN 110 and add to Classifier Block 1 with an
•Create a second classifier element with host 2’s IP address and VLAN 120 and add to Classifier Block 1 with an
•Create a Policy with Classifier block 1 and the Role Combination for port 1/3 with a non- match action of Bronze Service
At this time, it is only possible to combine L2 and L3 filters using policies. It is not possible to combine
12.6.1 ERS5500 Configuration – Using Policies
12.6.1.1 Create a Separate Role Combination for Port 1/3
ERS5500 Step 1 – Add new role combination for port 1/3 configured as untrusted and add port member 1/3
12.6.1.2 Add IP and L2 Classifiers Elements
ERS5500: Step 1 – Add IP elements with source address of 192.1.1.10
5500(config)#qos ip-element 1 src-ip 192.1.1.10/32
___________________________________________________________________________________________________________________________
Nortel Confidential Information Copyright © 2008 Nortel Networks. All Rights Reserved. |
|
External Distribution | 64 |