3.3.1.3 Tools / General Setpoints

The LCIC-WIM board has four digital outputs. Each of them may be defined

through the Tools / General Setpoints – either as a manual output, or as a general setpoint output:

A manual output is controlled by a user’s command sent from the PC (or another computer). That is, the user sends – either by his own application or by a general RS232 terminal (see section D.3) – commands to turn an output on or off. The user – and not the card – has the initiative to turn an output on or off.

A general setpoint output is controlled by the card according to user pre-defined criterion. Say, initially the user defined the setpoint as 10 kg, then the card automatically turns the output off/on when the current weight is less/more than 10 kg. The user cannot explicitly turn

an output on or off by a command.

Note – these general setpoints are absolutely different from the setpoints in the Fill mode (section E.4). The general setpoints are inactive in the Fill mode.

In order to configure an output:

Select output’s Mode as Manual or Setpoint.

In case you selected ‘Mode: Setpoint’, specify the setpoint value (e.g., 10).

Click ‘Save to Board’ to validate your new configuration.

You may turn each manual output on or off.

23

Page 24
Image 24
Omega Speaker Systems LCIC-WIM-BEN manual Tools / General Setpoints